Place of Origin : China
Brand Name : SX
Certification : CE,ISO9001
MOQ : 1 Set
Price : Negotiation
Packaging Details : Standard Export Wooden/Nude packing
Delivery Time : To be negotiated
Payment Terms : T/T; L/C
Temperature sensor : valve static nominal operating temperature 70℃ (valve closes automatically)
Item : Fire Damper
Valve body Material : 2~3mmQ235-A
Local resistance coefficient : Resistance coefficient of ≤ 0.5 at full opening
Rated voltage : DC24V±10%
Rated current : 0.7A
Fire dampers are passive fire protection products used in heating, ventilation, and air conditioning (HVAC) ducts to prevent the spread of fire inside the ductwork through fire-resistance rated walls and floors. Fire/smoke dampers are similar to fire dampers in fire resistance rating, and also prevent the spread of smoke inside the ducts. When a rise in temperature occurs, the fire damper closes, usually activated by a thermal element which melts at temperatures higher than ambient but low enough to indicate the presence of a fire, allowing springs to close the damper blades. Fire dampers can also close following receipt of an electrical signal from a fire alarm system utilising detectors remote from the damper, indicating the sensing of heat or smoke in the building occupied spaces or in the HVAC duct system.
| Fire damper performance parameter table | ||||
| Serial number | name | performance parameters | ||
| 1 | Standard flange specifications | Valve long side b or diameter D (mm) | Flange side width (mm) | |
| D≤280 | 20 | |||
| 280≤D≤630,b≤630 | 25 | |||
| 630<D1250,630<b≤1250 | 30 | |||
| 1250<D≤2000,1500<b≤2500 | 40 | |||
| D>2000,2500<b≤4000 | 50 | |||
| 2 | Temperature sensor | valve static nominal operating temperature 70℃ (valve closes automatically) | ||
| 3 | Material | Valve body | 2~3mmQ235-A | |
| Bles | 2mm708-88 Cold rolled plate | |||
| Axshaft | GB905-82 Cold pull round steel Ф12 | |||
| Axft sleeve | Oil-containing metallurgical powder copper sleeve | |||
| 4 | Local resistance coefficient | Resistance coefficient of ≤ 0.5 at full opening | ||
| 5 | Paint treatment | Ground floor rust proof primer (second floor), outer fire proof paint (medium ash steel paint) | ||
| 6 | Rated voltage | DC24V±10% | ||
| Rated current | 0.7A | |||
| Micro switch | AC380V,3A | |||
| Torque | 10~70Kg.f/cm | |||
| Action mode | automatic, electric, manual or 70℃ to close the valve | |||
| 7 | Fire control valve | Reset method (open state) | Manual reset | |
| Smoke and fire control valve | Manual reset | |||
| Smoke and fire damper | Manual reset | |||
| Remote control smoke and fire damper | Remote control manual reset | |||
| Automatic reset fire damper | Electric reset | |||
| 8 | Air leakage | In the standard state, when the pressure difference on both sides of the valve is 500Pa after the valve is closed, no more than 700mm³/㎡/h | ||

|
|